ETn1 indicates a motor parameter error, use of a two-pole or lower-capacity motor, low output voltage, motor rotation, or application to a load other than intended. The manual's first action is: “Check voltage and whether the motor has probe faults.”
- Model
- Schneider Electric ATV 21
- Display shows
- Auto-tuning error (ETn1)
- Type
- Fault code
- Source
- Manual p. 235
What ETn1 means
Auto-tuning error p. 235
Common causes
- Check motor parameters F402 (to F494). A motor with two-pole capacity or capacity lower than the inverter was used. Output voltage is too low. Motor is rotating. Inverter is applied to a load other than a three-phase induction motor. p. 235
What to do
- Check voltage and whether the motor has probe faults. p. 235
Before you service the product, read the safety instructions in the manual p. 8.
If ETn1 is still not resolved
This page summarises what the manufacturer’s manual says about ETn1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.