Error codeOP2
OP2 indicates overvoltage during acceleration, F3G5 operation disabled, or input voltage fluctuation. The manual's first action is: “Increase acceleration time dEC.”
- Model
- Schneider Electric ATV 21
- Display shows
- 000B (OP2)
- Type
- Error code
- Source
- Manual p. 234
What OP2 means
000B p. 234
Common causes
- Overvoltage during acceleration. p. 234
- F3G5 (overvoltage limit) operation is disabled. p. 234
- Input voltage fluctuates abnormally. p. 234
- (1) Voltage capacity is 200 kA or higher. p. 234
- (2) A power‑factor correction capacitor switch requests closure. p. 234
- (3) A thyristor‑based system is connected on the same power‑distribution line. p. 234
What to do
- Increase acceleration time dEC. p. 234
- Enable F3G5 (overvoltage limit) operation. p. 234
- Install a suitable input reactor. p. 234
Before you service the product, read the safety instructions in the manual p. 8.
If OP2 is still not resolved
This page summarises what the manufacturer’s manual says about OP2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.