Error codeOH
OH indicates over-torque, control fan not rotating, or ambient temperature too high. The manual's first action is: “Reset the inverter after it reaches sufficient torque and restart operation.”
- Model
- Schneider Electric ATV 21
- Display shows
- 0020 (OH)
- Type
- Error code
- Source
- Manual p. 234
What OH means
0020 p. 234
Common causes
- Over‑torque. p. 234
- Control fan not rotating. p. 234
- Ambient temperature too high. p. 234
- Ventilation holes blocked. p. 234
- Heat‑generating equipment installed near the inverter. p. 234
- Fan inside the equipment is worn out. p. 234
What to do
- Reset the inverter after it reaches sufficient torque and restart operation. p. 234
- Replace the fan if it does not rotate during operation. p. 234
- Ensure adequate air space around the inverter. p. 234
- Do not place any heat‑generating equipment in front of the inverter. p. 234
- Call the service phone number. p. 234
Before you service the product, read the safety instructions in the manual p. 8.
If OH is still not resolved
This page summarises what the manufacturer’s manual says about OH; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.