The F 4 code indicates an A14 4-20mA loss fault caused by loss of the 4-20 mA reference on analog input A14 or a power component fault. The manual's first action is: “Check the connection on the analog inputs”
- Model
- Schneider Electric Altivar 71W/E5
- Display shows
- [A14 4-20mA loss] (F 4)
- Type
- Fault code
- Source
- Manual p. 77
What F 4 means
[A14 4-20mA loss] p. 77
Common causes
What to do
Before you service the product, read the safety instructions in the manual p. 43.
If F 4 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about F 4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.