Schneider Electric Altivar 71W/E5 Error bLF: [BRAKE CONTROL FAULT]

Schneider Electric Altivar 71W/E5 · taken from the manufacturer’s manual, pages cited

Fault codebLF

The bLF code indicates a brake control fault caused by brake release current not reached or brake control parameters not set when brake logic control is assigned. The manual's first action is: “Check the drive/motor connection”

Model
Schneider Electric Altivar 71W/E5
Display shows
[BRAKE CONTROL FAULT] (bLF)
Type
Fault code
Source
Manual p. 77

What bLF means

[BRAKE CONTROL FAULT] p. 77

Common causes

  • Brake release current not reached p. 77
  • Brake control parameters not set when brake logic control is assigned p. 77

What to do

  1. Check the drive/motor connection p. 77
  2. Check the motor windings p. 77
  3. Apply the recommended settings (consult the CD-ROM supplied with the drive) p. 77

Before you service the product, read the safety instructions in the manual p. 43.

If bLF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about bLF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.