Schneider Electric Altivar 71 Error SCF2: [Impedant sh. circuit]

Schneider Electric Altivar 71 · taken from the manufacturer’s manual, pages cited

Fault codeSCF2

Impedant sh. circuit means significant earth leakage current at the drive output if several motors are connected in parallel. The manual's first action is: “Reduce the switching frequency.”

Model
Schneider Electric Altivar 71
Display shows
[Impedant sh. circuit] (SCF2)
Type
Fault code
Source
Manual p. 289

What SCF2 means

[Impedant sh. circuit] p. 289

Common causes

  • Significant earth leakage current at the drive output if several motors are connected in parallel p. 289

What to do

  1. Reduce the switching frequency. p. 289
  2. Connect chokes in series with the motor. p. 289
  3. Check the adjustment of speed loop and brake. p. 289

Before you service the product, read the safety instructions in the manual p. 16.

If SCF2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about SCF2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.