Schneider Electric Altivar 61 Error SOF: [Overspeed]

Altivar 61 drive · taken from the manufacturer’s manual, pages cited

Fault codeSOF

The overspeed fault is caused by instability or driving load too high. The manual's first action is: “Check the motor, gain and stability parameters. Add a braking resistor. Check the size of the motor/drive/load.”

Model
Schneider Electric Altivar 61
Display shows
[Overspeed] (SOF)
Type
Fault code
Source
Manual p. 54

What SOF means

[Overspeed] p. 54

Common causes

  • Instability or driving load too high p. 54

What to do

  1. Check the motor, gain and stability parameters. Add a braking resistor. Check the size of the motor/drive/load. p. 54

Before you service the product, read the safety instructions in the manual p. 33.

If SOF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about SOF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.