Schneider Electric Altivar 61 Error OCF: [Overcurrent]

Altivar 61 drive · taken from the manufacturer’s manual, pages cited

Fault codeOCF

The overcurrent fault is caused by incorrect motor parameters, inertia or load too high, or mechanical locking. The manual's first action is: “Check the parameters. Check the size of the motor/drive/load. Check the state of the mechanism.”

Model
Schneider Electric Altivar 61
Display shows
[Overcurrent] (OCF)
Type
Fault code
Source
Manual p. 54

What OCF means

[Overcurrent] p. 54

Common causes

  • Incorrect motor parameters p. 54
  • Inertia or load too high p. 54
  • Mechanical locking p. 54

What to do

  1. Check the parameters. Check the size of the motor/drive/load. Check the state of the mechanism. p. 54

Before you service the product, read the safety instructions in the manual p. 33.

If OCF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about OCF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.