Fault codeSLF
The code SLF indicates a Modbus bus communication interruption or a remote terminal LCC set to YES while disconnected. The manual's first action is: “Check the communication bus.”
- Model
- Schneider Electric Altivar 31
- Display shows
- Modbus fault (SLF)
- Type
- Fault code
- Source
- Manual p. 42
What SLF means
Modbus fault p. 42
Common causes
- Modbus bus communication interrupted p. 42
- Confirmation of remote terminal LCC = YES and terminal disconnected p. 42
What to do
- Check the communication bus. p. 42
- Please refer to the product-specific documentation. p. 42
- Check the display terminal connection. p. 42
If SLF is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about SLF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.
