Schneider Electric Altivar 31 Error LAF: auto-tuning fault

Altivar 31 variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeLAF

The code LAF indicates a special or non-adapted motor or a motor not connected to the drive. The manual's first action is: “Use the L or the P ratio (Uft page 34).”

Model
Schneider Electric Altivar 31
Display shows
auto-tuning fault (LAF)
Type
Fault code
Source
Manual p. 42

What LAF means

auto-tuning fault p. 42

Common causes

  • Special motor or motor whose power is not suitable for the drive p. 42
  • Motor not connected to the drive p. 42

What to do

  1. Use the L or the P ratio (Uft page 34). p. 42
  2. Check the presence of the motor during auto-tuning. p. 42
  3. If a downstream contactor is being used, close it during auto-tuning. p. 42

If LAF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about LAF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.