Schneider Electric Altivar 31 Error E EF: EEPROM fault

Altivar 31 variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeE EF

The code E EF indicates an internal memory fault. The manual's first action is: “Check the environment (electromagnetic compatibility). Replace the drive.”

Model
Schneider Electric Altivar 31
Display shows
EEPROM fault (E EF)
Type
Fault code
Source
Manual p. 41

What E EF means

EEPROM fault p. 41

Common causes

  • internal memory fault p. 41

What to do

  1. Check the environment (electromagnetic compatibility). Replace the drive. p. 41

If E EF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about E EF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.