Schneider Electric Altivar 21 Error Err7: Current sensor fault

Altivar 21 variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeErr7

Current sensor fault means a motor current sensor is inoperable. The manual's first action is: “Replace the drive.”

Model
Schneider Electric Altivar 21
Display shows
Current sensor fault (Err7)
Type
Fault code
Source
Manual p. 118

What Err7 means

Current sensor fault p. 118

Common causes

  • A motor current sensor is inoperable. p. 118

What to do

  1. Replace the drive. p. 118

Before you service the product, read the safety instructions in the manual p. 5.

If Err7 is still not resolved

  • contact Schneider Electric service p. 5
    “Schneider Electric accepts no responsibility for the consequences of using this device”
  • contact a qualified technician p. 6
    “Installation, adjustment, repair, and maintenance must be performed by qualified personnel”

This page summarises what the manufacturer’s manual says about Err7; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.