Schneider Electric Altivar 21 Error EPH0: Output phase loss

Altivar 21 variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeEPH0

Output phase loss means one or more output phases are lost. The manual's first action is: “Determine the cause of the missing output phase (such as a bad connection, an output disconnect, or an open winding in the motor) and rectify the problem. Set parameter F605 to 0.”

Model
Schneider Electric Altivar 21
Display shows
Output phase loss (EPH0)
Type
Fault code
Source
Manual p. 118

What EPH0 means

Output phase loss p. 118

Common causes

  • Loss of one or more output phases p. 118

What to do

  1. Determine the cause of the missing output phase (such as a bad connection, an output disconnect, or an open winding in the motor) and rectify the problem. Set parameter F605 to 0. p. 118

Before you service the product, read the safety instructions in the manual p. 5.

If EPH0 is still not resolved

  • contact Schneider Electric service p. 5
    “Schneider Electric accepts no responsibility for the consequences of using this device”
  • contact a qualified technician p. 6
    “Installation, adjustment, repair, and maintenance must be performed by qualified personnel”

This page summarises what the manufacturer’s manual says about EPH0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.