Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
MOTOWELD DIGITAL I/F FILE# ERROR indicates file number is set incorrectly between 1 and 16. The manual's first action is: “Set the user file number 1...16.”
MOTOWELD DIGITAL I/F ERROR indicates digital interface error, possibly due to damaged LAN cable or incorrect protocol type for VEW01. The manual's first action is: “Confirm the following content. (1) LAN cable is not …
MOTOWELD DIGITAL I/F NODE ERROR indicates node communication failure between welder power sources and robot controller. The manual's first action is: “Check the Node of the each welder power sources and robot controll…
MOTOWELD DIGITAL I/F WDG.ERROR indicates a watchdog error in digital interface, possibly due to damaged LAN cable or incorrect Ethernet settings. The manual's first action is: “Confirm the following content. (1) The L…
MOTOWELD WATER UNDER-FLOW indicates insufficient cooling water supply or circuit problem. The manual's first action is: “(1)Fill up the cooling water. (2)Check the circuit of cooling water.”
MOTOWELD INPUT UNDER-VOLTAGE indicates input voltage is too low, possibly due to environmental conditions or filter issues. The manual's first action is: “(1)Check the ambient temperature (40 degrees centigrade or les…
MOTOWELD EXCESSIVE TEMPERATURE indicates overheating due to ambient temperature or dust clogging on filters. The manual's first action is: “(1)Check the ambient temperature (40 degrees centigrade or less) and operatio…
MOTOWELD INPUT OVER-VOLTAGE indicates input voltage exceeds safe levels. The manual's first action is: “Confirm the input voltage.”
MOTOWELD OUTPUT OVER-CURRENT indicates output overload, likely from grounded cables, contact tip touching workpiece, or encoder cable issues. The manual's first action is: “Confirm the following content. (1) Check tha…
MOTOWELD INPUT OVER-CURRENT indicates excessive current input, possibly due to short-circuit or broken power circuit. The manual's first action is: “(1)Check if the output cable is short-circuited or grounded. (2) The…
MOTOWELD SYSTEM RESET is an error indicating the system has reset and requires shutdown after completion. The manual's first action is: “When finish system reset, Shut down the welding power source.”
Err150 error code from Fronius power source indicates a main error with sub-code 150. The manual's first action is: “Check the power supply of the power source Confirm the Fronius's manual”
EDg 1 error code from Fronius power source indicates a main error with sub-code 110. The manual's first action is: “Update firmware, otherwise change the UST board Confirm the Fronius's manual”
Error 109 indicates a Fronius power source assertion error. The manual's first action is: “Update firmware, otherwise change the UST board Confirm the Fronius's manual”
Error 108 indicates a Fronius power source error related to dog state detection. The manual's first action is: “Update firmware, otherwise change the UST board Confirm the Fronius's manual”