Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Err062 occurs when the machine is overheated; it requires allowing cooling and confirming the Fronius's manual for further steps. The manual's first action is: “Allow the machine to cool Confirm the Fronius's manual”
ErrArc indicates a main error code from the Fronius power source, with sub-code 61** showing specific details. The manual's first action is: “Confirm the Fronius's manual”
Err060 indicates a main error code from the Fronius power source, with sub-code 60** showing specific details. The manual's first action is: “Confirm the Fronius's manual”
Err059 requires confirmation of the Fronius's manual for specific error details and resolution steps. The manual lists no action for this code.
NoArc indicates a seam issue during welding, requiring inspection of the seam itself. The manual's first action is: “Confirm the Fronius's manual”
NoGAS indicates that gas volume is low, requiring verification of remaining gas supply. The manual's first action is: “Confirm the Fronius's manual”
Err056 occurs when insufficient wire remains on the spool; it should be resolved by checking and replacing the spool if necessary. The manual's first action is: “Confirm the Fronius's manual”
NoIGn indicates ignition failure, which may result from setting a lower Ito value or maintaining too large a torch stand-off distance before ignition. The manual's first action is: “Confirm the Fronius's manual”
Err054 occurs when burn-back control is insufficient or wire stick is enabled; it can be resolved by increasing BBC or disabling "Wire stick". The manual's first action is: “Confirm the Fronius's manual”
ErrPE indicates a low-resistance connection between the secondary and machine housing, requiring investigation into the cause. The manual's first action is: “Confirm the Fronius's manual”
Mains voltage too high or NT 24 defective is an error indicating either excessive mains voltage or a faulty NT 24 component. The manual's first action is: “Confirm the Fronius's manual”
Err051 indicates a main error code from the Fronius power source, with sub-code 51** showing specific details. The manual's first action is: “Mains voltage too low or NT 24 defective Confirm the Fronius's manual”
Err050 indicates a main error code from the Fronius power source, with sub-code 50** showing specific details. The manual's first action is: “Disconnect NT60 or change/check NT24/UST/BPS/intermediate circuit capacitor…
Err049 indicates an error from the Fronius power source with sub-code 49. The manual's first action is: “Check the mains power supply Check all 3 phases Confirm the Fronius's manual”
unknown indicates an error from the Fronius power source with sub-code 48, possibly not in use. The manual's first action is: “OR NOT IN USE Confirm the Fronius's manual”