Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
TPS: SELECTED UNREGISTERED PROGRAM means a welding program not prepared for the power source was selected, requiring reselection of an appropriate program. The manual's first action is: “Select again a welding program.”
Sub Code: MOTOWELD's Err Code. indicates an incorrect power source class setting (350A/500A), requiring confirmation of current class, switching dip switch SW600, and updating software accordingly. The manual's first …
Sub Code: MOTOWELD's Err Code. means a connection or dip switch issue between front panel and main board, requiring checking status, replacing components as needed. The manual's first action is: “(1)Check the connecti…
Sub Code: MOTOWELD's Err Code. indicates an abnormal movement of PLD causing the welding power supply to reboot, requiring replacement of main board with part code Pr (MB)-030 and contacting Yaskawa representative. Th…
Sub Code: MOTOWELD's Err Code. means data loading issues require not turning off power, reloading data if possible, or using a special tool if problems persist. The manual's first action is: “(1)Do not turn off the po…
Sub Code: MOTOWELD's Err Code. indicates a system reset issue requiring reboot of the power source. The manual's first action is: “Reboot the power source.”
Sub Code: MOTOWELD's Err Code. means the main board is faulty and requires replacement with part code UNIT-Pr (MB)-030, contacting Yaskawa representative. The manual's first action is: “Replace the main board (Service…
Sub Code: MOTOWELD's Err Code. indicates a front panel issue requiring replacement with part code UNIT-Pr (CR)-030, contacting Yaskawa representative. The manual's first action is: “Replace the front panel (Service pa…
Sub Code: MOTOWELD's Err Code. means the main board is faulty and requires replacement with part code UNIT-Pr (MB)-030, contacting Yaskawa representative. The manual's first action is: “Replace the main board (Service…
Sub Code: MOTOWELD's Err Code. indicates an unspecified error requiring loading of a suitable database. The manual's first action is: “Load the suitable database.”
MOTOWELD ILLEGAL WELD TYPE means an invalid welding type has been selected and must be set to a valid user-defined file in the robot controller. The manual's first action is: “Set a welding type to user file of MOTOWE…
MOTOWELD POWER SUPPLY ERROR indicates a general power supply failure, requiring replacement of either the switching power supply unit or main board for MOTOWELD-RP500 models. The manual's first action is: “The use of …
MOTOWELD +15V POWER SUPPLY ERROR means the +15V power supply is malfunctioning and requires replacement of either the switching power supply unit or main board for MOTOWELD-RP500 models. The manual's first action is: …
MOTOWELD OVER-VOLTAGE signifies an over-voltage condition detected by MOTOWELD, requiring contact with a Yaskawa representative. The manual's first action is: “Contact your Yaskawa representative.”
MOTOWELD MOMENTARY OVER-CURR indicates a short-circuit or earth grounding issue in the output cable, possibly with a broken power circuit. The manual's first action is: “(1)Check that short-circuit or the earth ground…