Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Grid underfrequency means the grid frequency is lower than the inverter's minimum acceptable limit. The manual's first action is: “set range.”
All 32 error codes of the Sungrow SG125HV/SG125HV-20 solar inverter with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
An error code greater than 8 was returned by the slave, indicating an unspecified issue. The manual lists no action for this code.
The slave detected a parity error while attempting to read extended memory. The manual lists no action for this code.
The slave cannot perform the program function received in the command due to constraints. The manual lists no action for this code.
The slave is currently processing a long-duration command and cannot respond immediately. The manual lists no action for this code.
The slave accepted the request but requires a long duration to process it. The manual lists no action for this code.
An unrecoverable error occurred while the slave attempted to perform the requested action. The manual lists no action for this code.
The data value being written is out of range or is being written to a read-only address on the slave. The manual lists no action for this code.
The data address referenced in the Master command does not exist or access to it is denied on the slave. The manual lists no action for this code.
The function code sent by the Master is not supported or has incorrect parameters on the slave device. The manual lists no action for this code.
The first word of string data contains a negative, zero, or value greater than 82. The manual's first action is: “Check the first word of the string data element for invalid values and correct the data.”
An expansion I/O object (that is cable, power supply, or module) in the user program I/O configuration is not the same object type as is physically present. The manual's first action is: “Correct the user program I/O …
Either an expansion I/O power supply is configured in the user program, but no power supply is present, or an expansion I/O power supply is configured in the user program and a power supply is physica The manual's fir…
Either an expansion I/O cable is configured in the user program, but no cable is present, or an expansion I/O cable is configured in the user program and a cable is physically present, but the types d The manual's fir…