Omron SYSDRIVE 3G3MZ Error HPF4: Overcurrent detection circuit abnormal (HPF4)

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeHPF4

Overcurrent detection circuit abnormal (HPF4) means an abnormality occurs in the overcurrent detection circuit. The manual's first action is: “→ Internal circuit abnormal → After detecting the abnormality, turn the power OFF/ON → If the abnormality persists after repeatedly turning the power OFF/ON, replace the inverter”

Model
Omron SYSDRIVE 3G3MZ
Display shows
Overcurrent detection circuit abnormal (HPF4) (HPF4)
Type
Error code
Source
Manual p. 169

What HPF4 means

Overcurrent detection circuit abnormal (HPF4) p. 169

Common causes

  • Abnormality occurs in the overcurrent detection circuit p. 169

What to do

  1. → Internal circuit abnormal → After detecting the abnormality, turn the power OFF/ON → If the abnormality persists after repeatedly turning the power OFF/ON, replace the inverter p. 169

Before you service the product, read the safety instructions in the manual p. 170.

If HPF4 is still not resolved

  • contact service or dealer p. 170
    “警告发生时,请根据下表来检测原因,采取妥当的措施”

This page summarises what the manufacturer’s manual says about HPF4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.