Omron SYSDRIVE 3G3MZ Error AOL2: Over-torque detection (AOL2)

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeAOL2

Over-torque detection (AOL2) means a mechanical abnormality (e.g., mechanical lockup) or a parameter setting error has occurred. The manual's first action is: “→ Eliminate the cause of the mechanical abnormality”

Model
Omron SYSDRIVE 3G3MZ
Display shows
Over-torque detection (AOL2) (AOL2)
Type
Error code
Source
Manual p. 170

What AOL2 means

Over-torque detection (AOL2) p. 170

Common causes

  • Mechanical abnormality (e.g., mechanical lockup) p. 170
  • Parameter setting error p. 170

What to do

  1. → Eliminate the cause of the mechanical abnormality p. 170
  2. → Set n6.04 (over-torque detection level) and n6.05 (over-torque detection time) to values appropriate for the machinery (increase the setting of n6.04 or n6.05) p. 170

Before you service the product, read the safety instructions in the manual p. 170.

If AOL2 is still not resolved

  • contact service or dealer p. 170
    “警告发生时,请根据下表来检测原因,采取妥当的措施”

This page summarises what the manufacturer’s manual says about AOL2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.