Error codeA.30

The A.30 code indicates a regeneration error due to regeneration resistor or regeneration circuit damaged. The manual's first action is: “Replace the Servo Driver.”

Model
Omron OMNUC W Series
Display shows
Regeneration error (A.30)
Type
Error code
Source
Manual p. 364

What A.30 means

Regeneration error p. 368

Common causes

  • Regeneration resistor or Regeneration circuit damaged due to large amount of regenerative energy. p. 368
  • Occurs during operation. p. 368
  • Error in the regenerative circuit parts. p. 368
  • External Regeneration Resistor is burned out. p. 368
  • Apart from a short-circuit between B2 and B3, the external circuit resistor is not connected. p. 368

What to do

  1. Replace the Servo Driver. p. 368
  2. Replace the External Regeneration Resistor. p. 368
  3. Correctly connect the external circuit resistor (between B1 and B2). p. 368

Before you service the product, read the safety instructions in the manual p. 6.

If A.30 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about A.30; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.