The A.10 code indicates overcurrent detected, or improper radiation shield temperature rise detected. The manual's first action is: “Replace the Servo Driver.”
- Model
- Omron OMNUC W Series
- Display shows
- Overcurrent (A.10)
- Type
- Error code
- Source
- Manual p. 364
What A.10 means
Overcurrent p. 368
Common causes
- Overcurrent detected, or improper radiation shield temperature rise detected. (1.5 to 3 kW only). p. 368
- Occurs when power supply is turned ON. p. 368
- Occurs when servo is turned ON. p. 368
- Current feedback circuit error p. 368
- Main circuit transistor module error p. 368
- Servomotor power line is short-circuited or grounded between phases. p. 368
- Miswiring between U-phase, V-phase, W-phase, and ground. p. 368
- Servomotor winding is burned out. p. 368
- Ambient Servo Driver temperature exceeds 55°C. p. 368
- Radiation shield air convection is poor. p. 368
- The fan has stopped. p. 368
- Operating above rated output. p. 368
What to do
- Replace the Servo Driver. p. 368
- Repair the short-circuited or grounded wire. Measure the insulation resistance at the Servomotor and, if there is a short-circuit, replace the Servomotor. p. 368
- Correct the wiring. p. 368
- Measure the winding resistance, and if the winding is burned out, replace the Servomotor. p. 368
- Lower the Servo Driver's ambient temperature to 55°C or less. p. 368
- Mount according to mounting conditions. p. 368
- Lighten the load. p. 368
Before you service the product, read the safety instructions in the manual p. 6.
If A.10 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.
This page summarises what the manufacturer’s manual says about A.10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.