Omron OMNUC W Series Error A.CC

Omron OMNUC W Series AC Servomotors Servo Drivers · taken from the manufacturer’s manual, pages cited

Alarm codeA.CC

The A.CC code occurs when you change the setting for user parameter Pn205 (absolute encoder multi-turn limit setting), and turn OFF the power supply to the Servo Driver and then back ON again. The manual's first action is: “When this alarm occurs, you can change the setting in the encoder to the same as the Servo Driver setting by means of Fn013 (absolute encoder multi-turn setting change). After changing the setting, turn OFF the power, then turn it ON again, to clear the A.CC alarm.”

Model
Omron OMNUC W Series
Display shows
A.CC
Type
Alarm code
Source
Manual p. 358

What A.CC means

When you change the setting for user parameter Pn205 (absolute encoder multi-turn limit setting), and turn OFF the power supply to the Servo Driver and then back ON again. p. 358

Common causes

  • When you change the setting for user parameter Pn205 (absolute encoder multi-turn limit setting), and turn OFF the power supply to the Servo Driver and then back ON again. p. 358

What to do

  1. When this alarm occurs, you can change the setting in the encoder to the same as the Servo Driver setting by means of Fn013 (absolute encoder multi-turn setting change). After changing the setting, turn OFF the power, then turn it ON again, to clear the A.CC alarm. p. 358

Before you service the product, read the safety instructions in the manual p. 6.

If A.CC is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about A.CC; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.