Omron OMNUC W Series Error A.32: Regeneration overload

Omron OMNUC W Series AC Servomotors Servo Drivers · taken from the manufacturer’s manual, pages cited

Error codeA.32

The A.32 code indicates regeneration overload when regenerative energy exceeded the regeneration resistance. The manual's first action is: “Calculate the regenerative energy, and connect an external Regeneration Resistor with the required regeneration absorption capacity.”

Model
Omron OMNUC W Series
Display shows
Regeneration overload (A.32)
Type
Error code
Source
Manual p. 364

What A.32 means

Regeneration overload p. 368

Common causes

  • Regenerative energy exceeded the regeneration resistance. p. 368
  • Occurs during operation. p. 368
  • Regenerative energy exceeds tolerance. p. 368
  • Setting error in Pn600 (regeneration resistor capacity) p. 368

What to do

  1. Calculate the regenerative energy, and connect an external Regeneration Resistor with the required regeneration absorption capacity. p. 368
  2. Set Pn600 correctly. p. 368

Before you service the product, read the safety instructions in the manual p. 6.

If A.32 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about A.32; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.