Omron F3SJ-A Error 71: Auxiliary output 1 error

Safety light curtain · taken from the manufacturer’s manual, pages cited

Fault code71

This error occurs when the diagnostic function for auxiliary output 1 is enabled and the auxiliary output wiring is shorted to 24 V, 0 V, or another non-external-device monitoring input line, the auxiliary output wiring is damaged, the load connected to auxiliary output 1 is damaged, or there is an auxiliary output 1 circuit fault. The manual's first action is: “Wire auxiliary output 1 correctly.”

Model
Omron F3SJ-A
Display shows
Auxiliary output 1 error (71)
Type
Fault code
Source
Manual p. 204

What 71 means

Auxiliary output 1 error p. 204

Common causes

  • When the diagnostic function for auxiliary output 1 is enabled, the auxiliary output wiring is shorted to 24 V, 0 V, or another non‑external‑device monitoring input line, or the auxiliary output wiring is damaged. p. 204
  • The load connected to auxiliary output 1 (e.g., indicator lamp or relay) is damaged. p. 204
  • Auxiliary output 1 circuit fault. p. 204

What to do

  1. Wire auxiliary output 1 correctly. p. 204
  2. Replace the load. p. 204
  3. Replace the F3SJ. p. 204

Before you service the product, read the safety instructions in the manual p. 7.

If 71 is still not resolved

  • contact Omron's service department p. 6
    “请保证遵守这些注意事项。”
  • contact Omron's service department p. 7
    “非拟定的功能设置可能使人员不能被检测从而导致严重伤害。”