Omron F3SJ-A Error 20: Blanking monitor error

Safety light curtain · taken from the manufacturer’s manual, pages cited

Error code20

This error occurs when a fixed blanking beam is illuminated other than the permitted beams or when the number of blocked beams is less than the allowed amount. The manual's first action is: “Adjust the device position so that fixed blanking beams other than the allowed beams are not illuminated. Or reconfigure the fixed blanking settings. p.64”

Model
Omron F3SJ-A
Display shows
Blanking monitor error (20)
Type
Error code
Source
Manual p. 201

What 20 means

Blanking monitor error p. 201

Common causes

  • A fixed blanking beam is illuminated other than the permitted beams. p. 201
  • The number of blocked beams is less than (number of floating blanking beams – allowed beams). p. 201

What to do

  1. Adjust the device position so that fixed blanking beams other than the allowed beams are not illuminated. Or reconfigure the fixed blanking settings. p.64 p. 201
  2. Set the number of floating blanking beams and allowed beams according to the size of the obstructing object. p.68 p. 201

Before you service the product, read the safety instructions in the manual p. 7.

If 20 is still not resolved

  • contact Omron's service department p. 6
    “请保证遵守这些注意事项。”
  • contact Omron's service department p. 7
    “非拟定的功能设置可能使人员不能被检测从而导致严重伤害。”

This page summarises what the manufacturer’s manual says about 20; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.