Omron F3SJ-A Error 70: External indicator output error

Safety light curtain · taken from the manufacturer’s manual, pages cited

Fault code70

This error occurs when the diagnostic function for external indicator output is enabled and the external indicator output is shorted to 24 V, 0 V, or another I/O line, the external indicator output wiring is damaged, the load connected to the external indicator output is damaged, or there is an external indicator circuit fault. The manual's first action is: “Wire the connections correctly.”

Model
Omron F3SJ-A
Display shows
External indicator output error (70)
Type
Fault code
Source
Manual p. 204

What 70 means

External indicator output error p. 204

Common causes

  • When the diagnostic function for external indicator output is enabled, the external indicator output is shorted to 24 V, 0 V, or another I/O line, or the external indicator output wiring is damaged. p. 204
  • The load connected to the external indicator output (e.g., indicator lamp or relay) is damaged. p. 204
  • External indicator circuit fault. p. 204

What to do

  1. Wire the connections correctly. p. 204
  2. Replace the load. p. 204
  3. Replace the F3SJ. p. 204

Before you service the product, read the safety instructions in the manual p. 7.

If 70 is still not resolved

  • contact Omron's service department p. 6