Error codePR0120
The machine detected an attempt to use synchronous feed when it is not specified in the system capabilities. The manual's first action is: “Check the specifications.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- No synchronous feed spec. (PR0120)
- Type
- Error code
- Source
- Manual p. 480
What PR0120 means
No synchronous feed spec. p. 480
Common causes
- Synchronous feed was commanded even though there are no synchronous feed specifications. p. 480
What to do
- Check the specifications. p. 480
- Change the synchronous feed command (G95) to a feed per minute command (G94). (Also change the F command value.) p. 480
Before you service the product, read the safety instructions in the manual p. 4.
If PR0120 is still not resolved
This page summarises what the manufacturer’s manual says about PR0120; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.