A plane selection command was issued while the tool radius compensation was active, which is not permitted. The manual's first action is: “Issue the plane selection command after the tool radius compensation command has been completed (issue the G40 cancel command.)”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Plane selected during R compen (PR0112)
- Type
- Error code
- Source
- Manual p. 480
What PR0112 means
Plane selected during R compen p. 480
Common causes
- A plane selection command (G17, G18, G19) has been issued when the tool radius compensation command (G41, G42) is issued. p. 480
What to do
- Issue the plane selection command after the tool radius compensation command has been completed (issue the G40 cancel command.) p. 480
Before you service the product, read the safety instructions in the manual p. 4.
If PR0112 is still not resolved
This page summarises what the manufacturer’s manual says about PR0112; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.