The machine detected a plane selection command issued during a coordinate rotation command, which is not allowed. The manual's first action is: “Upon completion of the G68 command, the plane selection command must be issued following the G69 command (coordinate rotation cancel). (For the program based on the M2/M0 format, the coordinate rotation command is G68.1 and the coordinate rotation cancel command is G69.1.)”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Coord rotation plane selection (PR0111)
- Type
- Error code
- Source
- Manual p. 480
What PR0111 means
Coord rotation plane selection p. 480
Common causes
- A plane selection command (G17, G18, G19) has been issued in a coordinate rotation command (G68). p. 480
What to do
- Upon completion of the G68 command, the plane selection command must be issued following the G69 command (coordinate rotation cancel). (For the program based on the M2/M0 format, the coordinate rotation command is G68.1 and the coordinate rotation cancel command is G69.1.) p. 480
Before you service the product, read the safety instructions in the manual p. 4.
If PR0111 is still not resolved
This page summarises what the manufacturer’s manual says about PR0111; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.