Error codeAL-38
Z phase open error caused by motor/drive combination failure, encoder cable issue, or encoder malfunction. The manual's first action is: “Check brand label code of motor and drive.”
- Model
- LS Mecapion L7P INDEXER Series
- Display shows
- Z phase open (AL-38)
- Type
- Error code
- Source
- Manual p. 272
What AL-38 means
Z phase open p. 272
Common causes
- Drive / Motor combination error p. 272
- Encoder cable error p. 272
- Encoder error p. 272
- Drive error p. 272
What to do
- Check brand label code of motor and drive. p. 272
- Wiring is incorrect and check Short p. 272
- Replace encoder cable. p. 272
- If alarm continue after servo on again, Replace drive. Because drive may have problem. p. 272
If AL-38 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact LS Mecapion service.
This page summarises what the manufacturer’s manual says about AL-38; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with LS Mecapion. Found a mistake? Report an error.