Error codeAL-42
Main power fail caused by incorrect voltage, parameter error, or momentary power loss. The manual's first action is: “check voltage between phase 200-230[Vac] of L1, L2, L3”
- Model
- LS Mecapion L7P INDEXER Series
- Display shows
- Main power fail (AL-42)
- Type
- Error code
- Source
- Manual p. 272
What AL-42 means
Main power fail p. 272
Common causes
What to do
- check voltage between phase 200-230[Vac] of L1, L2, L3 p. 272
- Check setting value arroding to state of main power [0x2006] p. 272
- Check setting value [0x2007] p. 272
If AL-42 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact LS Mecapion service.
This page summarises what the manufacturer’s manual says about AL-42; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with LS Mecapion. Found a mistake? Report an error.