Fault codeErr16

Err16 indicates communication fault due to host computer not operating correctly, communication cable abnormal, or communication expansion card FO-28 settings incorrect. The manual's first action is: “1. Check host computer wiring”

Model
Inovance MD380M
Display shows
Communication Fault (Err16)
Type
Fault code
Source
Manual p. 215

What Err16 means

Communication Fault p. 215

Common causes

  • 1. Host computer not operating correctly p. 215
  • 2. Communication cable abnormal p. 215
  • 3. Communication expansion card FO-28 settings incorrect p. 215
  • 3. Communication parameter FD group settings incorrect p. 215

What to do

  1. 1. Check host computer wiring p. 215
  2. 2. Inspect communication cable p. 215
  3. 3. Set communication expansion card type correctly p. 215
  4. 4. Set communication parameters correctly p. 215

Before you service the product, read the safety instructions in the manual p. 8.

If Err16 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err16; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.