Err14 indicates module overheat due to ambient temperature too high, air duct blocked, or fan damaged. The manual's first action is: “1. Lower ambient temperature”
- Model
- Inovance MD380M
- Display shows
- Module Overheat (Err14)
- Type
- Error code
- Source
- Manual p. 215
What Err14 means
Module Overheat p. 215
Common causes
- 1. Ambient temperature too high p. 215
- 2. Air duct blocked p. 215
- 3. Fan damaged p. 215
- 4. Module thermistor damaged p. 215
- 5. Inverter module damaged p. 215
- 6. Carrier frequency set too high; fan damaged or air duct blocked; internal servo drive components damaged (thermocouple or others); p. 215
What to do
- 1. Lower ambient temperature p. 215
- 2. Clean the air duct p. 215
- 3. Replace the fan p. 215
- 4. Replace the thermistor p. 215
- 5. Replace the inverter module p. 215
- 6. Reduce carrier frequency (F0-15). Replace fan, clean air duct. Seek manufacturer service. p. 215
Before you service the product, read the safety instructions in the manual p. 8.
If Err14 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err14; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.