Outdoor unit fan motor error occurs when motor rotation speed is below 100 RPMs in 20 seconds after starting. The manual's first action is: “After fan motor restarts, if the same operation within 60 seconds is repeated 3 times in a row, compressor and fan motor stops.”
- Model
- Fujitsu General 410A
- Display shows
- Outdoor unit fan motor error (97)
- Type
- Error code
- Source
- Manual p. 11
What 97 means
Outdoor unit fan motor error p. 11
Common causes
- Outdoor Unit Fan Motor Error – When outdoor fan motor rotation speed is less than 100 RPMs in 20 seconds after fan motor starts, fan motor stops. p. 11
- -Check rotation of fan, locked motor, or resistance for motor to rotate. p. 11
- -Check ambient temperature around motor, excessive high temperature around motor or surrounding equipment that causes heat. p. 11
What to do
- After fan motor restarts, if the same operation within 60 seconds is repeated 3 times in a row, compressor and fan motor stops. p. 11
- (Ref. Service Tip #008-Fan Motor Check and/or “Fan Motor Error” under “Troubleshooting by Error Code” Type In Zendesk Help Center) p. 11
If 97 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.
This page summarises what the manufacturer’s manual says about 97; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.