Error codeC1
This code indicates that serial communication data between CNC and spindle amplifier module is abnormal. The manual's first action is: “(a) SVPM failure – replace the SVPM or its control PCB.”
- Model
- FANUC B-65325CM/01
- Display shows
- C1
- Type
- Error code
- Source
- Manual p. 177
What C1 means
Serial communication data between CNC and spindle amplifier module is abnormal. p. 177
Common causes
- Serial communication data between CNC and spindle amplifier module is abnormal. p. 177
What to do
- (a) SVPM failure – replace the SVPM or its control PCB. p. 177
- (b) CNC failure – replace the board or module related to the serial spindle. p. 177
Before you service the product, read the safety instructions in the manual p. 3.
If C1 is still not resolved
This page summarises what the manufacturer’s manual says about C1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.