Alarm codeA1
This code indicates that the control program has not entered operational state. The manual's first action is: “An abnormality was detected in the control program processing.”
- Model
- FANUC B-65325CM/01
- Display shows
- A1
- Type
- Alarm code
- Source
- Manual p. 176
What A1 means
Control program has not entered operational state. p. 176
Common causes
- Control program has not entered operational state. p. 176
- This alarm appears when the spindle amplifier is powered on. p. 176
- Alarm occurs during motor excitation. p. 176
- If the spindle sensor signal cable is bundled together with the servo motor power line, separate them. p. 176
What to do
- An abnormality was detected in the control program processing. p. 176
- Replace the SVPM or its control PCB. p. 176
- Check the wiring related to the ground. p. 176
Before you service the product, read the safety instructions in the manual p. 3.
If A1 is still not resolved
This page summarises what the manufacturer’s manual says about A1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.