FANUC B-65325CM/01 Error A2

FANUC B-65325CM/01 · taken from the manufacturer’s manual, pages cited

Alarm codeA2

This code indicates that the control program has not entered operational state. The manual's first action is: “An abnormality was detected in the control program processing.”

Model
FANUC B-65325CM/01
Display shows
A2
Type
Alarm code
Source
Manual p. 176

What A2 means

Control program has not entered operational state. p. 176

Common causes

  • Control program has not entered operational state. p. 176
  • This alarm appears when the spindle amplifier is powered on. p. 176
  • Alarm occurs during motor excitation. p. 176
  • If the spindle sensor signal cable is bundled together with the servo motor power line, separate them. p. 176

What to do

  1. An abnormality was detected in the control program processing. p. 176
  2. Replace the SVPM or its control PCB. p. 176
  3. Check the wiring related to the ground. p. 176

Before you service the product, read the safety instructions in the manual p. 3.

If A2 is still not resolved

  • 请在故障的原因彻底清除之后再进行报警复位操作 p. 15
    “请在故障的原因彻底清除之后再进行报警复位操作”
  • 有关维护方面的疑问事项,请尽早与 FANUC 公司联络 p. 15
    “有关维护方面的疑问事项,请尽早与 FANUC 公司联络”