Encoder undetected because GP2 is set to "0" (sinewave encoder) but a Resolver is actually installed. The manual's first action is: “The value of GP2 must be consistent with the feedback device installed. Contact Fagor Automation.”
- Model
- FAGOR MAN REGUL (IN)
- Display shows
- Encoder undetected (801)
- Type
- Error code
- Source
- Manual p. 332
What 801 means
Encoder undetected p. 332
Common causes
- Parameter GP2 has been set to "0" (sinewave encoder) and the motor feedback is actually a Resolver. p. 332
What to do
- The value of GP2 must be consistent with the feedback device installed. Contact Fagor Automation. p. 332
If 801 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.