FAGOR MAN REGUL (IN) servo-drive system · taken from the manufacturer’s manual, pages cited

Error code203

Torque overload error occurs when the servo drive is locked and cannot turn freely due to excessive torque exceeding GP8 for too long. The manual's first action is: “Free the motor. If the error comes up for no apparent reason, increase the GP7 -F235- and/or GP8 -F236- values. If GP7 is set to "0", the error message is never issued.”

Model
FAGOR MAN REGUL (IN)
Display shows
Torque overload error. (203)
Type
Error code
Source
Manual p. 240

What 203 means

Torque overload error. p. 240

Common causes

  • - The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 -F235- value. p. 240
  • - The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 value. p. 240

What to do

  1. Free the motor. If the error comes up for no apparent reason, increase the GP7 -F235- and/or GP8 -F236- values. If GP7 is set to "0", the error message is never issued. p. 240
  2. Free the motor. If the error comes up for no apparent reason, increase the GP7 and/or GP8 values. If GP7 is set to "0", the error message is never issued. p. 240

If 203 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.

This page summarises what the manufacturer’s manual says about 203; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FAGOR. Found a mistake? Report an error.