Torque overload error occurs when the servo drive is locked and cannot turn freely due to excessive torque exceeding GP8 for too long. The manual's first action is: “Free the motor. If the error comes up for no apparent reason, increase the GP7 -F235- and/or GP8 -F236- values. If GP7 is set to "0", the error message is never issued.”
- Model
- FAGOR MAN REGUL (IN)
- Display shows
- Torque overload error. (203)
- Type
- Error code
- Source
- Manual p. 240
What 203 means
Torque overload error. p. 240
Common causes
- - The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 -F235- value. p. 240
- - The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 value. p. 240
What to do
- Free the motor. If the error comes up for no apparent reason, increase the GP7 -F235- and/or GP8 -F236- values. If GP7 is set to "0", the error message is never issued. p. 240
- Free the motor. If the error comes up for no apparent reason, increase the GP7 and/or GP8 values. If GP7 is set to "0", the error message is never issued. p. 240
If 203 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.