Delta VFD-VE 系列 Error ovA: During acceleration, the AC motor drive detected an over‑voltage on the internal high‑voltage DC side. 230 V: DC 450 V; 460 V: DC 900 V.

Delta VFD-VE AC motor drive · taken from the manufacturer’s manual, pages cited

Error codeovA

ovA on the Delta VFD-VE 系列 is listed in the manual as: During acceleration, the AC motor drive detected an over‑voltage on the internal high‑voltage DC side. 230 V: DC 450 V; 460 V: DC 900 V.. The manual's first action is: “Check that the input voltage is within the drive’s rated input range and monitor for voltage spikes. If the over‑voltage is caused by motor inertia voltage rebound, you can lengthen the deceleration interval or install a braking resistor (optional).”

Model
Delta VFD-VE 系列
Display shows
ovA
Type
Error code
Source
Manual p. 235

What ovA means

During acceleration, the AC motor drive detected an over‑voltage on the internal high‑voltage DC side. 230 V: DC 450 V; 460 V: DC 900 V. p. 235

Common causes

  • During acceleration, the AC motor drive detected an over‑voltage on the internal high‑voltage DC side. 230 V: DC 450 V; 460 V: DC 900 V. p. 235

What to do

  1. Check that the input voltage is within the drive’s rated input range and monitor for voltage spikes. If the over‑voltage is caused by motor inertia voltage rebound, you can lengthen the deceleration interval or install a braking resistor (optional). p. 235

Before you service the product, read the safety instructions in the manual p. 72.

If ovA is still not resolved

  • Contact local agents for consultation. p. 4
    “若有任 何疑虑的地方请连络本公司各地的代理商洽询,我们的专业人员会乐于为您服务。”

This page summarises what the manufacturer’s manual says about ovA; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.