Delta VFD-VE 系列 Error ocA: Overcurrent during acceleration; during acceleration, output current exceeds three times the inverter's rated current.

Delta VFD-VE AC motor drive · taken from the manufacturer’s manual, pages cited

Error codeocA

ocA on the Delta VFD-VE 系列 is listed in the manual as: Overcurrent during acceleration; during acceleration, output current exceeds three times the inverter's rated current.. The manual's first action is: “Check whether the U-V-W wiring to the motor has poor insulation; increase acceleration time.”

Model
Delta VFD-VE 系列
Display shows
ocA
Type
Error code
Source
Manual p. 235

What ocA means

Overcurrent during acceleration; during acceleration, output current exceeds three times the inverter's rated current. p. 235

Common causes

  • Overcurrent during acceleration; during acceleration, output current exceeds three times the inverter's rated current. p. 235

What to do

  1. Check whether the U-V-W wiring to the motor has poor insulation; increase acceleration time. p. 235

Before you service the product, read the safety instructions in the manual p. 72.

If ocA is still not resolved

  • Contact local agents for consultation. p. 4
    “若有任 何疑虑的地方请连络本公司各地的代理商洽询,我们的专业人员会乐于为您服务。”

This page summarises what the manufacturer’s manual says about ocA; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.