LUN on the Delta VFD-VE 系列 is listed in the manual as: During constant‑speed operation, the AC motor drive detected that the internal high‑voltage DC side voltage is lower than the setting in parameter 06‑00.. The manual's first action is: “Check whether the load has a sudden heavy overload.”
- Model
- Delta VFD-VE 系列
- Display shows
- LUN
- Type
- Error code
- Source
- Manual p. 236
What LUN means
During constant‑speed operation, the AC motor drive detected that the internal high‑voltage DC side voltage is lower than the setting in parameter 06‑00. p. 236
Common causes
- During constant‑speed operation, the AC motor drive detected that the internal high‑voltage DC side voltage is lower than the setting in parameter 06‑00. p. 236
What to do
- Check whether the load has a sudden heavy overload. p. 236
Before you service the product, read the safety instructions in the manual p. 72.
If LUN is still not resolved
- Contact local agents for consultation. p. 4 “若有任 何疑虑的地方请连络本公司各地的代理商洽询,我们的专业人员会乐于为您服务。”
This page summarises what the manufacturer’s manual says about LUN; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.