The inverter internal DC high‑voltage side voltage is too low. The manual's first action is: “1. Check whether the input power voltage is normal.”
- Model
- Delta VFD-P
- Display shows
- Inverter internal DC high‑voltage side voltage is too low (LU)
- Type
- Error code
- Source
- Manual p. 70
What LU means
Inverter internal DC high‑voltage side voltage is too low p. 70
Common causes
- Inverter internal DC high‑voltage side voltage is too low p. 70
What to do
- 1. Check whether the input power voltage is normal. p. 70
- 2. Check whether the load has a sudden heavy load. p. 70
- 3. Verify if a three‑phase machine is being supplied with a single‑phase input or is missing a phase. p. 70
Before you service the product, read the safety instructions in the manual p. 2.
If LU is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.