This is the list of error codes the Delta manual gives for the VFD-P Delta VFD-P. Find your code below and open it for what the manual says about its causes and what to do.
Error codes from p. 70
| Code | Display message | What it means | Page |
|---|---|---|---|
OC |
Inverter detects an abnormal surge of overcurrent on the output side | 变频器侦测输出侧有异常突增的过电流产生 | p. 70 |
OU |
Inverter detects an over‑voltage condition on the internal DC high‑voltage side | 变频器侦测内部直流高压侧有过电压现象产生 | p. 70 |
OH |
Inverter detects internal temperature too high, exceeding the protection threshold | 变频器侦测内部温度过高,超过保护位准 | p. 70 |
LU |
Inverter internal DC high‑voltage side voltage is too low | 变频器内部直流高压侧过低 | p. 70 |
OL |
Output current exceeds the inverter’s allowable current. The inverter can tolerate 120 % of its rated current for 60 seconds. | 输出电流超过变频器可承受的电流。若输出120%的变频器额定电流,可承受60秒。 | p. 70 |
OL1 |
Internal electronic thermal protection activation | 内部电子热动电驿保护动作 | p. 70 |
OL2 |
Motor load is too large | 电机负载太大 | p. 70 |
Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Delta. Found a mistake? Report an error.