Low voltage means the DC bus voltage has fallen below its minimum value. The manual's first action is: “1. Check whether the input voltage falls within the AC motor drive rated input voltage range. 2. Check for abnormal load in motor. 3. Check for correct wiring of input power to R-S-T (for 3-phase models) without phase loss.”
- Model
- Delta VFD-M-D
- Display shows
- Low voltage (LV)
- Type
- Fault code
- Source
- Manual p. 141
What LV means
Low voltage p. 141
Common causes
- The AC motor drive detects that the DC bus voltage has fallen below its minimum value. p. 141
What to do
- 1. Check whether the input voltage falls within the AC motor drive rated input voltage range. 2. Check for abnormal load in motor. 3. Check for correct wiring of input power to R-S-T (for 3-phase models) without phase loss. p. 141
Before you service the product, read the safety instructions in the manual p. 4.
If LV is still not resolved
- contact your dealer p. 4 “If you have any questions, please contact your dealer.”
This page summarises what the manufacturer’s manual says about LV; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.