Delta Electronics VFD002DD2 1A Error Lun: Lun Voltage Below Setting Detected on Internal DC High-Voltage Side During Constant-Speed Operation

Delta VFD002DD2 1A · taken from the manufacturer’s manual, pages cited

Error codeLun

The Lun code indicates during constant speed operation, the AC motor drive detected that the internal DC high-voltage side voltage is lower than the setting of 06-00. The manual's first action is: “Check whether the input power voltage is normal; check if the load has a sudden overload.”

Model
Delta Electronics VFD002DD2 1A
Display shows
Lun
Type
Error code
Source
Manual p. 106

What Lun means

Lun Voltage Below Setting Detected on Internal DC High-Voltage Side During Constant-Speed Operation p. 106

Common causes

  • During constant speed operation, AC motor drive detected that the internal DC high-voltage side voltage is lower than the setting of 06-00, causing the condition. p. 106

What to do

  1. Check whether the input power voltage is normal; check if the load has a sudden overload. p. 106

Before you service the product, read the safety instructions in the manual p. 2.

If Lun is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta Electronics service.

This page summarises what the manufacturer’s manual says about Lun; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta Electronics. Found a mistake? Report an error.