AL026 indicates an encoder internal data reliability error due to encoder error (internal data abnormal three consecutive times). The manual's first action is: “1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid.”
- Model
- Delta ASDA-B2 series
- Display shows
- Encoder internal data reliability error (AL026)
- Type
- Error code
- Source
- Manual p. 161
What AL026 means
Encoder internal data reliability error p. 161
Common causes
- Encoder error (internal data abnormal three consecutive times) p. 161
What to do
- 1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid. p. 161
- 1. Connect the grounding terminal (green) of the UVW connector to the driver’s heat‑sink area. 2. Check the encoder signal wires to ensure they are properly separated from power lines or high‑current circuits. 3. Use cable that includes a shielded braid. 4. If the issue does not improve, return the unit to the dealer or original manufacturer for service. p. 161
Before you service the product, read the safety instructions in the manual p. 122.
If AL026 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL026; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.