Delta ASDA-B2 series Error AL025: Encoder internal error

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Fault codeAL025

AL025 indicates an encoder internal error due to encoder internal error (internal memory fault, internal counting fault). The manual's first action is: “1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid.”

Model
Delta ASDA-B2 series
Display shows
Encoder internal error (AL025)
Type
Fault code
Source
Manual p. 160

What AL025 means

Encoder internal error p. 160

Common causes

  • Encoder internal error (internal memory fault, internal counting fault) p. 160

What to do

  1. 1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid. p. 160
  2. 1. Connect the grounding terminal (green) of the UVW connector to the driver’s heat‑sink area. 2. Inspect the encoder signal wires to ensure they are properly separated from power lines or high‑current circuits. 3. Use cable that includes a shielded braid. 4. If the problem does not improve, return the unit to the dealer or original manufacturer for service. p. 160

Before you service the product, read the safety instructions in the manual p. 122.

If AL025 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL025; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.