AL025 indicates an encoder internal error due to encoder internal error (internal memory fault, internal counting fault). The manual's first action is: “1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid.”
- Model
- Delta ASDA-B2 series
- Display shows
- Encoder internal error (AL025)
- Type
- Fault code
- Source
- Manual p. 160
What AL025 means
Encoder internal error p. 160
Common causes
- Encoder internal error (internal memory fault, internal counting fault) p. 160
What to do
- 1. Verify that the motor ground terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder cable uses a shielded (isolated) braid. p. 160
- 1. Connect the grounding terminal (green) of the UVW connector to the driver’s heat‑sink area. 2. Inspect the encoder signal wires to ensure they are properly separated from power lines or high‑current circuits. 3. Use cable that includes a shielded braid. 4. If the problem does not improve, return the unit to the dealer or original manufacturer for service. p. 160
Before you service the product, read the safety instructions in the manual p. 122.
If AL025 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL025; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.