Delta ASDA-B2 series Error AL024: Encoder initial magnetic field error

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Error codeAL024

AL024 indicates an encoder initial magnetic field error due to encoder initial magnetic field error (UVW field position error). The manual's first action is: “1. Verify that the motor ground terminal is properly grounded 2. Ensure encoder signal wires are separated from power or high‑current lines to avoid interference 3. Confirm that encoder cables use shielded (isolated) wiring”

Model
Delta ASDA-B2 series
Display shows
Encoder initial magnetic field error (AL024)
Type
Error code
Source
Manual p. 160

What AL024 means

Encoder initial magnetic field error p. 160

Common causes

  • Encoder initial magnetic field error (UVW field position error) p. 160

What to do

  1. 1. Verify that the motor ground terminal is properly grounded 2. Ensure encoder signal wires are separated from power or high‑current lines to avoid interference 3. Confirm that encoder cables use shielded (isolated) wiring p. 160
  2. If the issue persists, return to dealer or manufacturer for service p. 160

Before you service the product, read the safety instructions in the manual p. 122.

If AL024 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL024; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.