Delta ASDA-B series Error F: Forward limit switch error

Delta ASDA-B series · taken from the manufacturer’s manual, pages cited

Fault codeF

F indicates a forward limit switch error when any of digital inputs DI1~DI6 signal is set to Forward inhibit limit (CCWL) and the signal is ON. The manual's first action is: “If it is no need to use "Forward inhibit limit (CCWL)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI8 are not set to "Forward inhibit limit (CCWL)". (The setting value of parameter P2-10 to P2-15 is not set to 23.)”

Model
Delta ASDA-B series
Display shows
Forward limit switch error (F)
Type
Fault code
Source
Manual p. 98

What F means

Forward limit switch error p. 98

Common causes

  • Please check if any of digital inputs DI1~DI6 signal is set to "Forward inhibit limit (CCWL)" and check if the signal is ON or not. p. 98
  • If it is necessary to use "Forward inhibit limit (CCWL)" as input signal, the users only need to confirm that which of digital inputs DI1~DI6 is set to "Forward inhibit limit (CCWL)" and check if the digital input signal is ON (It should be activated). p. 98

What to do

  1. If it is no need to use "Forward inhibit limit (CCWL)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI8 are not set to "Forward inhibit limit (CCWL)". (The setting value of parameter P2-10 to P2-15 is not set to 23.) p. 98

Before you service the product, read the safety instructions in the manual p. 3.

If F is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.